Technology

http://www.omod.no/?demobilizaciya=bin%C3%A4re-optionen---meine-geschichte&300=05 binäre optionen - meine geschichte At the hearth of the UltraWAVE is a Teflon-lined 1 liter stainless steel reaction chamber, which serves both as a microwave cavity and a reaction vessel.
Samples are weighed into vials, and suitable reagents are added. Vials are placed in a rack, which is automatically lowered into the reaction chamber. The chamber is sealed and pre-pressurized with inert gas, which physically acts as a cap for the vials, avoiding boiling of the solutions and preventing cross contamination.
At the completion of the microwave run, a built-in cooling device rapidly lowers the temperature.


Digestion sequence

Digestion sequence

STEP 1

broker finanziario Sample rack is lowered automatically into microwave chamber

Digestion sequence

STEP 2

http://www.mylifept.com/?refriwerator=gute-charts-f%C3%BCr-bin%C3%A4re-optionen&698=59 gute charts für binäre optionen Chamber clamp is secured by the operator

Digestion sequence

STEP 3

تداول الخيارات الثنائية في الولايات المتحدة الأمريكية Chamber is pre-pressurized with inert gas to prevent sample boiling

Digestion sequence

STEP 4

binary options trading signals members area Microwave energy is applied.
All samples under same temperature and pressure

Digestion sequence

STEP 5

bara Cialis Very fast cooling step due to water cooling of chamber

Digestion sequence

STEP 6

http://shepline.com/?soba=strategia-vincente-in-opzioni-binarie&1fb=68 strategia vincente in opzioni binarie Clamp is released and sample rack automatically rises from chamber


Improved workflow

31 in 60 sekunden mit binary options verdienen The UltraWAVE operates up to 199 bar pressure and 300°C. Unlike all conventional microwave digestion systems, every sample is under direct temperature and pressure and temperature control- no needs to rely on a reference vessel or to an indirect control such as infrared temperature sensors.
This assures complete control of the digestion process in every sample.
All sample types are digested at the same temperature and pressure even with different acid mixtures and volumes.
Moreover the UltraWAVE thanks to the Automatic Gas Module further improves the lab throughput.

UltraWAVE Safety

Safety

autopzionibinarie con paypal A thick acrylic shield surrounds the work area, which lowers into position automatically as the chamber is closed.
The PID controller monitors pressure, digestion and chamber temperature 20 times/sec, adjusting microwave power to control even highly exothermic reactions.

UltraWAVE fast cooling

Fast cooling

binära optioner aftonbladet At the completion of the microwave run, the UltraWAVE built-in water cooling device enables the temperature to lower from 270°C to 80°C in just 12 minutes.
Once the system reach the set cooling temperature, automatically releases the pressure from all the vials simultaneously.

UltraWAVE fast cooling
[+] ZOOM
  • Low operating cost
  • Low operating cost

Low operating costs

خيار ثنائي الروبوت funziona No vessel assembly/disassembly is required, vessel cleaning is eliminated with disposable glass vials, and method development is virtually eliminated.
There are also major savings on consumables costs, which is important for high throughput labs using closed vessel digestion.
Racks from 4 to 22 positions are available with vials made of quartz, PTFE/TFM or disposable glass vials, in order to match even very low blanks level.
Ask to your local Milestone Specialist the best configuration for your needs.


User interface

free forex scalping system userinterfaceThe UltraWAVE is operated via a compact control terminal with easy-to-read, bright, full-color, touch- screen display.

http://swazilandforum.com/?n=forum-opzione-binarie forum opzione binarie Hundreds of applications, including all US EPA methods, are preloaded in the UltraWAVE terminal.

opcje binarne matt The terminal is provided with multiple USB and RS-232 ports for direct printout of microwave methods and runs, and for interfacing the instrument to external peripherals.

swiss binäre optionen The terminal runs the Milestone’s unique multi-language EasyCONTROL software, to provide simple, user-friendly control of the microwave sample preparation process. Simply recall a factory-stored method or create a new one; press ‘START’ and the system will automatically follow the user defined temperature or pressure profile, utilizing a sophisticated PID algorithm to regulate the microwave power.





  • Download catalog
  • Play video
  • Request more info
  • Request application